To define this unit as a slave unit in the
network, choose SLA.
Only one unit in the network can be defined as master
unit. All slave units will respond to and send informa-
tion to the master unit. Time, day of week and econo-
my periods will be controlled from the master unit. All
other settings must be specified for each slave unit.
No more than 32 units can be combined in a network
including independent units (even though these units
do not communicate with the master unit).
2. Press the button once to confirm your selection.
ECtemp 550
16 Installation Guide