Temperature range 5-35°C with room sensor
5-45°C with floor sensor only
Floor max 20-50°C
Floor min 10-35°C, when instal-
led with combination of room
and floor sensor
Cable specification max
1x4mm
2
or 2x2,5mm
2
Ball pressure tempera-
ture
75°C
Pollution degree 2 (domestic use)
Type 1C
Storage temperature -20°C to +65°C
IP class 31
Protection class
Class II -
Dimensions 85 x 85 x 54mm (in-wall depth:
24mm)
Weight 107g
The product complies with the EN/IEC Standard "Automatic
electrical controls for household and similar use":
EN/IEC 60730-1 (general)
EN/IEC 60730-2-7 (timer)
EN/IEC 60730-2-9 (thermostat)