The screen of the heating cable must be connected to
the earth conductor of the power supply cable by us-
ing a separate connector.
Note: Always install the floor sensor in a conduit in the
floor.
3. Mount and reassemble the thermostat.
Fasten the thermostat to a socket or an exterior wall
box by driving the screws through the holes in each
side of the thermostat.
Tighten the screws to fasten the thermostat.
4. Turn on the power supply.
Initially main supply the thermostat for 15 hours to fully
charge the battery. The current time and day is then kept
for 80 days if mains supply is off. All other settings are stor-
ed permanently.
ECtemp 535
10 Installation Guide