2.4. Connecting the power supply:
The heat pump is available in these designs and regulating the location of wiring:
Internal electronics installation. Place for
the management of the heat pump.There is
no room for placement AVS37, therefore
suitable for combination with QAA78.
RVS41
AVS37
cable AVS-RVS
Compressor contractor
fan relay 3f
terminal
Circuit breaker control
All electronics and controller in an external
cabinet. The front panel space to
accommodate AVS37.
The rack is a space for installing the
contractors and circuit breakers bivalence,
auxiliary relay, etc.
Supplied with connecting cable harness
with connectors, the standard length of 3m.
RVS41
AVS37
cable AVS-RVS
Compressor contactor
fan relay 3f
terminal
switch
Circuit breaker control
Compressor circuit breaker
Switchboard wiring system
3 m
Outdoor electronics unit has always been
outsourced. Supplied with connecting cable
harness connectors standard 5m.
RVS41
AVS37
cablet AVS-RVS
Compressor contactor
fan relay 3f
terminal
switch
Circuit breaker control
Compressor circuit breaker
Switchboard wiring system
5 m
Heat pump Hotjet with the electronics
located in the distribution of indoor
unit.Between indoor and outdoor unit must
be carried out according to the
interconnection scheme. Cable not
included.
RVS41
AVS37
cablet AVS-RVS
Compressor contactor
terminal
switch
Circuit breaker control
Compressor circuit breaker
Heat pump earth water is the internal
electronics of a standard switchboard.
Place for the management of the heat
pump. There is no room for placement
AVS37, therefore suitable for combination
with QAA78.
RVS41
AVS37
cablet AVS-RVS
Compressor contactor
terminal
Circuit breaker control
Hotjet CZ s.r.o.! ! 15 z 46
Operating instructions and installation of heat pumps Hotjet (3.08/2010/01)
!!