Solar-Log500: Configuration at the unit
Configuring system settings (“System” menu)
196 of 268 Solar-Log
1000/500/200
Installation
9.3.4 Configuring a large display (System/Large display)
Large displays can be connected to the Solar-Log
500
using 2 different technol-
ogies.
Through the S0 pulse output
Through the RS485 (recommended)
It is recommended to use the RS485 connection, as in this case the numerical
values in Solar-Log™ are synchronised with the values shown on the display.
If certain inverters are used (Fronius, Eaton/Suntension), however, the S0 in-
terface must be used since parallel operation is not possible.
In this case, data on the large display can only be used correctly if inverter
configuration has been completed and the inverters are feeding in.
Setting the display on the S0 output
1 In the menu, select System/Large display/Display S0
2 Enter the pulse factor
The pulse factor must match that of the display
(Default: 1000).
3 Press ENTER to save
Setting the display on RS485
1 In the menu, select System/Large display/Display RS485
2 Enter the pulse factor
The pulse factor must match that of the display
(Default: 1000).
3 Press ENTER to save
If no inverters are configured on the RS485 interface (e.g. in Bluetooth mode),
the Solar-Log
500
transmits at 9600 Baud, 8N1.