Connecting the inverters
Connection accessories
16 of 268 Solar-Log
1000/500/200
Installation
4 Connecting the inverters
As each inverter manufacture uses different wiring connections and connect-
ors, the corresponding data cables must be adapted correctly:
You will find the terminal strip block wiring diagram to connect the in-
verters in table form in the following sections on connecting inverters.
For assignment of the RS485/422 B connection to the Solar-Log™,
see page 14.

Note
Solare Datensysteme GmbH supplies suitable connection cables for most
inverter manufacturers.
Always read the manufacturer-specific instructions for connecting the data ca-
ble. You will find these instructions in the manufacturer's documentation.
However, when assigning the inverter wiring on the Solar-Log™ side
(RS485/422 B connection), follow the instructions in this manual, otherwise
the inverters will not be detected by Solar-Log™.
DANGER
Risk of death by electric shock if inverters are opened.
Never open the inverter housing when the inverter is live.
Switch inverters off; Page 17
Always read the installation and safety instructions given in the manu-
al for the corresponding inverter.
Any work on inverters must only be carried out by trained electricians.
CAUTION
Damage to the electrical components in inverters and on interface cards due
to electrostatic discharge.
Avoid contact with component connections and plug contacts.
Before picking up a component, earth yourself by holding the PE or
unpainted part of the inverter housing.
CAUTION
Damage to the electronic components of the Solar-Log™ when wiring the
Solar-Log™!
Switch the Solar-Log™ off; Page 17