GB
3.5 Typical Fully Pumped System with 3-Port
Mid-Position Valve
N L 1 2 3 4 5 6
3 amp fuse
D.H.W. HTG
ON OFF
Mains
Supply
N
L
Programmer
Terminals
N
N
3-port
mid pos
valve
Room
Stat
ON OFF
N
Boiler
& Pump
Cyl.
Stat
Links
Other Danfoss Randall products suitable for use with above circuit:-
AT cylinder thermostat
HS3 3-port mid-position valve with spring return actuator.