Datasheet RET24 and RET230
RET230
Electronics
N
L 1
2
3
4
}
Voltage Free
N
L
220/240V
°C
°C
RET230NSB
C
NC
NO
Electronics
N
L
2
3
4
}
Voltage Free
N
L
220/240V
°C
°C
RET230VF, RET230VF2
C
NC
NO
Electronics
N
L
3
4
L
N
220/240V
°C
°C
RET230, RET230L, RET230C 1)
1) RET230C has SPST contacts.
Part No. 294 Issue 08 03/07
Electronics
N
L 1
2
3
4
}
Voltage Free
°C
°C
RET230NSB
C
NC
NO
Electronics
N
L 1
2
3
4
}
Voltage Free
°C
°C
RET230NSB
C
NC
NO
Electronics
N
L 1
2
3
4
}
Voltage Free
°C
°C
RET230NSB
C
NC
NO
N
L
220/
240V
N
L
Electronics
A
B C
2
3
4
}
Voltage Free
N
L
24V
°C
°C
RET24NSB
C
NC
NO
Electronics
A
B
2
3
4
}
Voltage Free
L
N
24V
°C
°C
RET24VF
Electronics
A
B
3
4
L
N
24V
°C
°C
RET24
Electronics
A
B C
2
3
4
}
Voltage Free
°C
°C
RET24NSB
C
NC
NO
Electronics
A
B C
2
3
4
}
Voltage Free
°C
°C
RET24NSB
C
NC
NO
Electronics
A
B C
2
3
4
}
Voltage Free
°C
°C
RET24NSB
C
NC
NO
N
L
24V
N
L
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Randall Ltd.
Ampthill Road
Bedford MK42 9ER
Tel: 0845 1217 400
Fax: 0845 1217 515
Email: danfossrandall@danfoss.com
Website: www.danfoss-randall.co.uk
Typical Application
Multiple zones -
RET230’s NSB controlled by one timeswitch.
Timeswitch with volt free contacts
Typical Application
Multiple zones -
RET24’s NSB controlled by one timeswitch.
Timeswitch with volt free contacts
VDRBW202
2
Datasheet RET24 and RET230
RET230
Electronics
N
L 1
2
3
4
}
Voltage Free
N
L
220/240V
°C
°C
RET230NSB
C
NC
NO
Electronics
N
L
2
3
4
}
Voltage Free
N
L
220/240V
°C
°C
RET230VF, RET230VF2
C
NC
NO
Electronics
N
L
3
4
L
N
220/240V
°C
°C
RET230, RET230L, RET230C 1)
1) RET230C has SPST contacts.
Part No. 294 Issue 08 03/07
Electronics
N
L 1
2
3
4
}
Voltage Free
°C
°C
RET230NSB
C
NC
NO
Electronics
N
L 1
2
3
4
}
Voltage Free
°C
°C
RET230NSB
C
NC
NO
Electronics
N
L 1
2
3
4
}
Voltage Free
°C
°C
RET230NSB
C
NC
NO
N
L
220/
240V
N
L
Electronics
A
B C
2
3
4
}
Voltage Free
N
L
24V
°C
°C
RET24NSB
C
NC
NO
Electronics
A
B
2
3
4
}
Voltage Free
L
N
24V
°C
°C
RET24VF
Electronics
A
B
3
4
L
N
24V
°C
°C
RET24
Electronics
A
B C
2
3
4
}
Voltage Free
°C
°C
RET24NSB
C
NC
NO
Electronics
A
B C
2
3
4
}
Voltage Free
°C
°C
RET24NSB
C
NC
NO
Electronics
A
B C
2
3
4
}
Voltage Free
°C
°C
RET24NSB
C
NC
NO
N
L
24V
N
L
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Randall Ltd.
Ampthill Road
Bedford MK42 9ER
Tel: 0845 1217 400
Fax: 0845 1217 515
Email: danfossrandall@danfoss.com
Website: www.danfoss-randall.co.uk
Typical Application
Multiple zones -
RET230’s NSB controlled by one timeswitch.
Timeswitch with volt free contacts
Typical Application
Multiple zones -
RET24’s NSB controlled by one timeswitch.
Timeswitch with volt free contacts
VDRBW202
Data Sheet Room Thermostat RMT
Danfoss Randall can accept no responsibility for possible errors in catalogues, brochures and other printed material, and reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
1 - 2 opens on increase in temperature 1 - 3 closes on increase in temperature
Dimensions
Electrical Connection
Part No: 352 Iss.4. 05/99












Datasheet
3
TP5000 Si Programmable Room Thermostat
Part No. 082 Issue 1 10/06
The Service interval timer allows the installer to
select a service due date for the boiler, this can
be set at between 28 days and 366 days from the
current date.
Service due date is within 28 days
From 28 days prior to the service due date, a visual
warning will appear in the display and a buzzer will
sound for ten seconds each hour commencing at
midday, this can be cancelled for the current day
by pressing any button.
Service Interval Timer Service due date is reached or passed
When the service due date is reached the visual
and audible warning are repeated each day
commencing at midday, but the duration of the
alarm is increased to 60 seconds, this can be
cancelled for the current day by pressing any
button. All override and programming buttons
are disabled and depending upon service interval
timer setting, heating can be restricted to 15, 30 or
45 minutes in each programmed hour.
Option Service Interval Timer Function
Setting 0 Disabled, (factory default)
Setting 1 Active, visual and audible warning, no heat reduction
Setting 2 Active, visual and audible warning, heat reduced to 45 minutes per hour
Setting 3 Active, visual and audible warning, heat reduced to 30 minutes per hour
Setting 4 Active, visual and audible warning, heat reduced to 15 minutes per hour
Speci cation and Ordering
Thermostat Features TP5000 Si TP5000-RF Si TP5000M Si
Sales code, built-in sensor 087N791000 087N791200 087N791700
Sales code, built in sensor c/w RX1 receiver 087N791400
Sales code, remote sensor inputs
1
087N791100 087N791800
5/2 day or 24 hour programmable room thermostat Yes, selectable by installer
2, 4 or 6 events per day with optional A/B programming Yes, selectable by installer
Factory pre-set programmes Yes, one for weekdays, another for weekends
Factory set calendar clock Automatic summer/wintertime change
Time accuracy ± 1 minute per year
Memory back-up, time and all user and installer settings Retained for life of product
Temperature range 5-30°C
Programmable frost thermostat function Yes
Control output, derived from PI algorithm On/O or Chrono-proportional, 3, 6, 9 or 12 cycles per hour
Switching di erential in On/O mode ±1°C
Installer selectable advanced programming options Yes, refer to table opposite
Installer selectable service interval timer Yes, 28 to 366 days from current date
Programmable range limitation Yes
Electronic keyboard lock Yes
Power supply 2 x AA alkaline cells 230V, 50Hz
Switching action of output relay
Switch rating of output relay 3 (1) A, 10-230V N/A 3 (1) A, 10-230V
Transmission frequency (RF models) N/A 433.92MHz N/A
Transmission range (RF models) N/A 30m max. N/A
Dimensions, mm 110 wide x 88 high x 28 deep
Design standard EN60730-2-9, (EN300220 for RF)
1
Can be con gured by installer for remote temperature sensor, limit sensor, window contact or telephone activated
Wiring TP5000 Si
Remote Input
(TP5000 Si only)
S1
S2
TP5000M Si
123
NONC COM
Heating
Load
S1
L
S2
Remote Input
(TP5000MA Si only
C
N
B
Electronics
N
Ph
123
NONC COM
Heating
Load
Please note:
On 230V version the power
supply is connected to L and N.
On the 24V version the power
supply is connected to A and B.
Datasheet
3
TP5000 Si Programmable Room Thermostat
Part No. 082 Issue 1 10/06
The Service interval timer allows the installer to
select a service due date for the boiler, this can
be set at between 28 days and 366 days from the
current date.
Service due date is within 28 days
From 28 days prior to the service due date, a visual
warning will appear in the display and a buzzer will
sound for ten seconds each hour commencing at
midday, this can be cancelled for the current day
by pressing any button.
Service Interval Timer Service due date is reached or passed
When the service due date is reached the visual
and audible warning are repeated each day
commencing at midday, but the duration of the
alarm is increased to 60 seconds, this can be
cancelled for the current day by pressing any
button. All override and programming buttons
are disabled and depending upon service interval
timer setting, heating can be restricted to 15, 30 or
45 minutes in each programmed hour.
Option Service Interval Timer Function
Setting 0 Disabled, (factory default)
Setting 1 Active, visual and audible warning, no heat reduction
Setting 2 Active, visual and audible warning, heat reduced to 45 minutes per hour
Setting 3 Active, visual and audible warning, heat reduced to 30 minutes per hour
Setting 4 Active, visual and audible warning, heat reduced to 15 minutes per hour
Speci cation and Ordering
Thermostat Features TP5000 Si TP5000-RF Si TP5000M Si
Sales code, built-in sensor 087N791000 087N791200 087N791700
Sales code, built in sensor c/w RX1 receiver 087N791400
Sales code, remote sensor inputs
1
087N791100 087N791800
5/2 day or 24 hour programmable room thermostat Yes, selectable by installer
2, 4 or 6 events per day with optional A/B programming Yes, selectable by installer
Factory pre-set programmes Yes, one for weekdays, another for weekends
Factory set calendar clock Automatic summer/wintertime change
Time accuracy ± 1 minute per year
Memory back-up, time and all user and installer settings Retained for life of product
Temperature range 5-30°C
Programmable frost thermostat function Yes
Control output, derived from PI algorithm On/O or Chrono-proportional, 3, 6, 9 or 12 cycles per hour
Switching di erential in On/O mode ±1°C
Installer selectable advanced programming options Yes, refer to table opposite
Installer selectable service interval timer Yes, 28 to 366 days from current date
Programmable range limitation Yes
Electronic keyboard lock Yes
Power supply 2 x AA alkaline cells 230V, 50Hz
Switching action of output relay
Switch rating of output relay 3 (1) A, 10-230V N/A 3 (1) A, 10-230V
Transmission frequency (RF models) N/A 433.92MHz N/A
Transmission range (RF models) N/A 30m max. N/A
Dimensions, mm 110 wide x 88 high x 28 deep
Design standard EN60730-2-9, (EN300220 for RF)
1
Can be con gured by installer for remote temperature sensor, limit sensor, window contact or telephone activated
Wiring TP5000 Si
Remote Input
(TP5000 Si only)
S1
S2
TP5000M Si
123
NONC COM
Heating
Load
S1
L
S2
Remote Input
(TP5000MA Si only
C
N
B
Electronics
N
Ph
123
NONC COM
Heating
Load
Please note:
On 230V version the power
supply is connected to L and N.
On the 24V version the power
supply is connected to A and B.
Datasheet
2
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Randall Ltd.
Ampthill Road
Bedford MK42 9ER
Tel: 0845 1217 400
Fax: 0845 1217 515
Email: danfossrandall@danfoss.com
Website: www.danfoss-randall.co.uk
FMT230D Flush Mount Room Thermostat
Features FMT230D
Code No 087N774400
Temperature Range 5 - 30°C
Setting knob and LCD display
O
Chrono-proportional or On/O control
O
Heat or cool operation
O
Output relay contact rating 10-250 Vac, 50/60 Hz, 3 (1) A
Switching action 1 SPDT
Power supply 230 Vac ± 10%, 50/60 Hz
Maximum ambient temperature 45°C
Dimensions (mm) 85 wide x 85 high x 35 deep
Speci cation and
Ordering Details
Wiring Details
Dimensions
Part No. 722v01 02/08
LN
ELECTRONICS
LN
230 Vac
COM
NO
NC
Wall
Wall
Standard UK
electrical box w/min
depth 25mm
16mm
85mm
85mm
85mm
Datasheet
2
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Randall Ltd.
Ampthill Road
Bedford MK42 9ER
Tel: 0845 1217 400
Fax: 0845 1217 515
Email: danfossrandall@danfoss.com
Website: www.danfoss-randall.co.uk
FMT230D Flush Mount Room Thermostat
Features FMT230D
Code No 087N774400
Temperature Range 5 - 30°C
Setting knob and LCD display
O
Chrono-proportional or On/O control
O
Heat or cool operation
O
Output relay contact rating 10-250 Vac, 50/60 Hz, 3 (1) A
Switching action 1 SPDT
Power supply 230 Vac ± 10%, 50/60 Hz
Maximum ambient temperature 45°C
Dimensions (mm) 85 wide x 85 high x 35 deep
Speci cation and
Ordering Details
Wiring Details
Dimensions
Part No. 722v01 02/08
LN
ELECTRONICS
LN
230 Vac
COM
NO
NC
Wall
Wall
Standard UK
electrical box w/min
depth 25mm
16mm
85mm
85mm
85mm
Thermostat RET Wiring:
Thermostat TP5000 / FMT Wiring:
TP5000 FMT230D
Thermostat RMT Wiring: